Multifocal intraocular lenses with fractal geometry

Lentes intraoculares multifocales de geometría fractal

By: L. Remón, W. D. Furlan, J. A. Monsoriu

Main Information

Volume:
Vol.48-N1 / 2015 - Ordinario
Section:
Vision Sciences
Pages:
1-8
DOI:
http://dx.doi.org/10.7149/OPA.48.1.1
Type:
Introduction to Research/Introducción a la Investigación
Language:
Spanish / Español
Attachments:
Keywords:
Optical quality, design, intraocular lenses.

Calidad Óptica, diseño, lente intraocular
PDF file download

Abstract

This paper is a summary of the results of the PhD entitled: Design, Fabrication and Quality Control of the Multifocal Intraocular Lenses presented and defended by L. Remon at Universitat Politecnica de Valencia (October 2012) and supervised by Prof. J.A Monsoriu and Prof. W.D. Furlan [1]. Multifocal IOLs (MIOLs) are a promising alternative to presbyopic patients (suffering from cataracts). There exist several commercially available models and designs of MIOLs, each one with its own drawbacks and advantages, evidencing that the optimum MIOL has not yet designed. This work presents the design, and quality control of a new design of MIOL with a fractal profile. This type of lenses provides an extended depth of field and a reduced chromatic aberration compared to other commercially available designs. Additionally, to assess the optical quality of MIOLs, two different experimental setups were designed "ad-hoc"; according to the requirements of the UNE ISO 11979-2 standard.


Esta publicación resume los resultados de la tesis doctoral: Diseño, Fabricación y Control de Calidad de Lentes Intraoculares Multifocales, presentada por L. Remón en la Universitat Politecnica de Valencia (Octubre de 2012) y dirigida por los profesores J.A Monsoriu y W.D. Furlan [1]. Las lentes multifocales (LIOMs) suponen una alternativa prometedora en pacientes de más de 50 años para la compensación de la presbicia. En el mercado existen gran disparidad de diseños multifocales, cada uno con sus ventajas e inconvenientes, lo que evidencia que la LIOM que ofrece las mejores prestaciones todavía no ha sido diseñada. En este trabajo se presentan resultados de diseño, fabricación y evaluación de la calidad óptica de un nuevo tipo de LIOMs, con geometría fractal, que presenta una mayor profundidad de foco y una menor aberración cromática con respecto a las que actualmente se encuentran en el mercado. Para la evaluación de la calidad óptica de las LIOMs propuestas se han desarrollado expresamente dos dispositivos experimentales basados en las especificaciones de la Norma UNE ISO 11979-2.

References

[1] L. Remón, Diseño, Fabricación y Control de Calidad de Lentes Intraoculares Multifocales, Tesis Doctoral, Universitat Politècnica de València (2012). http://riunet.upv.es/handle/10251/17703

[2] D. A. Atchison, "Design of aspheric intraocular lenses," Ophthal Physl Opt 11(2), 137-146 (1991). DOI

[3] B. Seitz, A. Langenbucher, "Intraocular lens power calculation in eyes after corneal refractive surgery," J Refract Surg 16, 349-361 (2000).

[4] R. Bellucci, A. Scialdone, L. Buratto, S. Morselli, C. Chierego, A. Criscuoli, G. Moretti, P. Piers, "Visual acuity and contrast sensitivity comparison between Tecnis and AcrySof SA60AT intraocular lenses: A multicenter randomized study," J Cataract Refr Surg 31, 712-717 (2003). DOI

[5] UNE-EN ISO 11979-2: Implantes oftalmicos. Lentes intraoculares. Parte 2: Propiedades opticas y métodos de ensayo. (ISO 11979-2:1999).

[6] UNE-EN ISO 11979-9: Implantes oftalmicos. Lentes intraoculares. Parte 9: Lentes intraoculares multifocales. (ISO 11979-9:2006).

[7] V. Portney, "Optical testing and inspection methodologyfor modern intraocular lenses," J Cataract Refr Surg 18(6), 607-613 (1992). DOI

[8] R. Rawer, W. Stork, C. W. Spraul, C. Lingenfelder,"Imaging quality of intraocular lenses," J Cataract Refr Surg 31(8), 1618-1631 (2005). DOI

[9] J. T. Holladay, H. Dijk, A. Lang, V. Portney, T. R. Willis, R. Sun, H.C. Oksman, "Optical performance of multifocal intraocular lenses," J Cataract Refr Surg 16, 413-422 (1990). DOI

[10] G. Saavedra, W.D. Furlan, J. A. Monsoriu, "Fractal Zone Plate," Opt Lett 28(12), 971-973 (2003). DOI

[11] J. A. Monsoriu, W.D. Furlan, G. Saavedra, F. Giménez, "Devil's Lenses," Opt Express 15(21), 13858-13864 (2007). DOI

[12] W. D. Furlan, G. Saavedra, J. A. Monsoriu, "White-light imaging with fractal zone plates," Opt Lett 32(15), 2109-2111 (2007). DOI

[13] W. D. Furlan, P. Andrés, G. Saavedra, A. Pons, J. A. Monsoriu, A. Calatayud, L. Remón, F. Giménez, J. L. Rojas, E. Larra, P. J. Salazar "Lente oftalmica multifocal y procedimiento para su obtención," PCT/ES2011/070559 (2010).

[14] A. Calatayud, L. Remón, J. Martos, J. A. Monsoriu, W. D. Furlan, "Imaging quality of multifocal intraocular lenses.Automated assessment setup," Ophthal Physl Opt 33, 320-326 (2013). DOI

[15] A. Calatayud, J. A. Rodrigo, L. Remón, W. D. Furlan, G. Cristobal, J. A. Monsoriu, "Experimental generation and characterization of Devil's vortex-lenses," Appl Phys B 106(4), 915-919 (2012). DOI

[16] L. Remón, A. Arias, A. Calatayud, W. D. Furlan, J. A. Monsoriu, "Through-focus response of multifocal intraocular lenses evaluated with a spatial light modulator," Appl Optics 36, 8594-8598 (2012). DOI